Failure and solution On line Service: longiemach@hotmai.com
Failure |
Reason |
Solution |
Lifting table does not lift |
Over low power |
Check starting electrical potential when motor runs with load, voltage liquid level range should be ±10%. |
Motor does not work |
Check motor and circuit |
|
Motor anti-rotate |
Exchange 2 wires positions of the 3 phases |
|
Default phase (motor no moving with abuzz) |
Check breaker and connection line of motor. |
|
Drop valve open |
When drop button is free, find out if there is power in drop valve. If no power, check circuit then; if there is power, remove the failure. The slide valve of the drop valve must keep clean and smart movable. |
|
Overflow valve low pressure |
Adjust the overflow valve, note: please adjust it under 100% loading. |
|
Oil level over low |
Fill in oil to full. |
|
Oil sucker of the fliter block |
Clean the filter |
|
Oil sucking section leak gas |
Check oil sucking pipe and the tie-in, screw down the tie-in. Change the tie-in if necessary |
|
Indicate light is on, press up button, motor runs but platform does’t move |
Check the contact of 3 phase power source, exchange the power connection, the motor anti-move, then exchange the power source is ok. |
|
Lifting table drop with no operation |
Unilateralism valve drainage |
Check the unilateralism valve in group valves, if there is dirty on the seal cover, then clean the unilateralism valve. |
Drop valve does not seal well |
Check if there is power in the drop valve, if there is power it is to say the valve is good. The slide valve of drop valve must keep clean and smart movable. |
|
Cylinder inner leak |
Exchange cylinder seal parts |
|
Lifting table does not drop |
Drop valve does not work |
Check out if there is power when pressing the button of drop. If there is no power, remove the failure, if there is power, remove the valve itself failure or change the drop valve. Drop valve should be clean and lube. |
Drop speed conrtrol valve out of control |
Adjust the drop speed control valve. |